Back

Technical specifications

Room sensor and controller 24V

Airobot 24V Heating Control handles both heating and cooling with ease.

  • It works with water-based floor heating and cooling, and can also control electric floor heating when paired with a relay.
  • The system can even manage both water and electric heating at the same time, switching between them automatically depending on the season.
  • For homes with fan-coil cooling, it can also control the fan using an optional expansion module.
  • All of this happens seamlessly in the background, keeping your indoor climate just right year-round.

Applications

  • Water underfloor heating control
  • Water underfloor cooling control
  • Control of electric floor heating with separate relay A-HC-R2416 (up to 16A)
  • Combined control of electric and water floor heating: simultaneous use with both water and electric floor heating
  • Management of water underfloor heating during the heating period; when switching to cooling in summer, water underfloor heating is automatically turned off and electric underfloor heating is activated
  • Fan-coil control with separate expansion module A-HC-EXTC

Features

  • Air temperature and humidity measurement
  • CO2 carbon dioxide measurement (only for room sensors marked -AQ)
  • Control via air temperature or floor sensor
  • Home and away mode of operation: different temperature setting points can be set for each mode
  • Network connection: Wi-Fi and LAN cable
  • Mobile application control with iOS and Android applications (network connection required)
  • Circulation pump control
  • Boiler control
  • House automation compatibility: Modbus TCP (coming over the air in 2025 with an upgrade)
  • Transmission of carbon dioxide CO2 readings to Airobot ventilation unit for air quality control of air flow
  • Automatic or manual change of heating and cooling mode
  • Prohibition of floor cooling by room
  • Automatic shutdown of floor cooling when the humidity in the room rises above the permissible limit (to prevent dew point)
  • Deactivation of floor cooling in away operation mode by room
  • Possibility to calibrate the temperature reading of the room sensor

Technical: Room Sensors

  • Supply voltage: From the room controller 24 V
  • Connectivity between the room sensor and the room controller: 4-core low-current cable 0.22 mm2 – 0.75 mm2, max. length 100 m. It is recommended to use a data cable.
  • IP protection class: IP20
  • Ambient temperature and humidity: +5 °C to 40 °C, max. 80% relative humidity (non-condensing)
  • Floor sensor: 10 kΩ NTC, max 0.75 mm2
  • Installation: Wall adapter included, EU wall case D68 mm or smooth wall, 60 mm gap between mounting screws
  • Temperature sensor: Digital, accuracy ±0.2 °C
  • Air humidity sensor: Digital, accuracy ±2%
  • Carbon dioxide (CO2) sensor: only on a model marked -AQ Photoacoustic, accuracy ±50 ppm + 5% reading
  • Compliance: EN 60730-1, EN 60730-2-9, EN 61000-6-2, EN 61000-6-4
  • Product dimensions: 82 x 89 x 11 mm
  • Product weight: 60 g
  • Package dimensions: 14 x 12.5 x 5 cm
  • Package weight: 125 g

Technical: Room Controller

  • Maximum number of room sensors: 8
  • Maximum heating zones: 8
  • Connectivity to room sensors: 4-core low-current cable, from 0.22 mm2 to 0.75 mm2, max. length 100 m. It is recommended to use a data cable.
  • Maximum number of actuators: 12 Actuators, output 24 V DC, NC normally closed, max. switching current 0,2 A
  • Power supply: 230 VAC 50 Hz (3 A) Power Max. 45 W
  • Power connection: 1 meter cord with EU connector
  • Ambient temperature and humidity: From 0 °C to 45 °C, max. 80% relative humidity (non-condensing)
  • Output relay 1: pump, maximum 100 W. Activated with 3 minute delay when at least 1 zone requests heating.
  • Output relay 2: boiler (RELAY) Potential-free NC/NO, maximum 2 A resistive or 1 A inductive. Activated with 3 minute delay when at least 1 zone requests heating.
  • Network connection: Wi-Fi 2.4 GHz or LAN with internet wire
  • Compatibility: iOS and Android mobile app
  • Compliance with standards: EN 60730-1, EN 60730-2-9, EN 61000-6-2, EN 61000-6-4
  • Dimensions: 244 x 55 x 120 mm
  • Weight: 1.25 kg
  • Package dimensions: 30 x 30 x 5.5 cm
  • Package weight: 1.6 kg

Connection diagram